electro-oculogram (EOG)
Also called EOG, electrooculogram, electro-oculography
The electro-oculogram (EOG) records the standing potential between the electrically positive cornea and the electrically negative back of the eye. The potential reflects the activity of the retinal pigment epithelium (RPE) and the photoreceptors.1
Electrodes on the skin at the inner and outer canthi pick up the potential as the patient looks alternately to extreme left and extreme right gaze.2 The potential is smaller in the dark and larger in the light, and the test reports the ratio of the light peak to the dark trough.1,2 Normal EOG amplitude varies widely from person to person, and the ratio, long called the Arden ratio, removes that variation.1,2
The EOG is most useful in diagnosing Best disease and in separating it from adult-onset vitelliform macular dystrophy and pattern dystrophy.3 Only diffuse or widespread RPE disease changes the response much, but widespread photoreceptor dysfunction always makes the EOG abnormal.1 The voltage between the electrodes also changes as the eye rotates, so the same recording can measure eye position.4
More detail
The potential reaches its dark trough after about 8 minutes of dark adaptation and its light peak after about 15 minutes of light adaptation.2 The sources set the normal limit of the ratio differently. One gives a normal value typically above 1.7, another says normal values exceed 1.5, and a third counts values below about 165% to 180% as abnormal.1,2,3 The 2017 update of the international (ISCEV) standard renamed the Arden ratio the light peak/dark trough (LP/DT) ratio.3
Sources (9)
- Kanski, Clinical Ophthalmology (2024), ch. 15
- Visual Perception: A Clinical Orientation, ch. 16
- Yanoff and Duker, Ophthalmology (2023), ch. 6.7
- Yanoff and Duker, Ophthalmology (2023), ch. 11.3
- Rutstein, R., Daum, K. (1997). Anomalies of Binocular Vision: Diagnosis & Management, Mosby.
- Leigh, R. J., & Zee, D. S. (2015). The neurology of eye movements. Oxford University Press, USA.
- Marmor, M. F., Brigell, M. G., McCulloch, D. L., Westall, C. A., & Bach, M. (2011). ISCEV standard for clinical electro-oculography (2010 update). Documenta Ophthalmologica, 122(1), 1-7.
- Thurtell, M. J., & Leigh, R. J. (2010). Nystagmus and saccadic intrusions. Handbook of clinical neurology, 102, 193-210.
- Garbutt, S., Han, Y., Kumar, A. N., Harwood, M., Harris, C. M., & Leigh, R. J. (2003). Vertical optokinetic nystagmus and saccades in normal human beings. Annals of the New York Academy of Sciences, 1004(1), 448-460.
Reviewed October 2026
Related terms
Nearby in the glossary
- eccentric fixation
- electro-oculogram (EOG)
- EnChroma glasses
- epicanthus
- esophoria